For open barrel terminals / contacts●Ideal for small contact pin crimping.(Die area has thin steps.)Wire sizesWeightgAWG#28 to #14200 Nominal sizesDie widthmmCrimp heightmmCompatible wire sizes (reference)Insulation OD(reference)mmφAWG#mm2For conductor1.41.40.728 to 240.08 to 0.20.7 to 1.21.7L1.728 to 220.08 to 0.30.9 to 1.51.7H1.124 to 180.2 to 0.82.0L2.00.928 to 180.08 to 0.81.1 to 1.82.0H1.324 to 180.2 to 0.82.4L2.41.220 to 160.5 to 1.251.3 to 2.22.4M1.516 to 141.25 to 2.0 Nominal sizesDie widthmmCrimp heightmmInsulation OD (reference)mmφFor insulation2.4H2.42.41.3 to 2.22.82.82.81.6 to 2.63.23.23.21.8 to 3.03.73.73.72.1 to 3.5For insulation(for round crimps)φ1.81.81.41.2 to 1.8φ2.52.52.11.8 to 2.5φ4.04.03.52.3 to 3.8Warning●The handle cover is not insulated. Do not use where electrical currents exist.
For open barrel terminals / contacts●15 various-sized dies make this product suitable for a wide range of terminal sizes, from small to large.●A toggle mechanism enables secure crimping by applying only a light force. (Die area has thin steps.)Wire sizesWeightgAWG#30 to #14320 Nominal sizesDie widthmmCrimp heightmmCompatible wire sizes(reference)AWG#mm2For conductor1.21.20.430 to 240.05 to 0.21.4L1.40.5530 to 200.05 to 0.51.7L1.70.6528 to 180.08 to 0.82.0L2.00.826 to 160.13 to 1.252.4L2.41.120 to 140.5 to 2.02.9L2.91.518 to 140.8 to 2.0 Nominal sizesDie widthmmCrimp heightmmInsulation OD (reference)mmφFor insulation1.41.41.10.7 to 1.21.71.71.30.9 to 1.52.02.01.351.1 to 1.82.42.41.751.3 to 2.22.92.921.6 to 2.63.53.52.41.9 to 3.24.24.22.62.3 to 3.8For insulation(for round crimps)φ1.61.61.51.0 to 1.6φ2.22.21.81.6 to 2.2Warning●The handle cover is not insulated. Do not use where electrical currents exist.
For modular plugs●A dedicated crimper for attaching modular plugs to 4 and 6 wire modular cords.Equipped with a dedicated wire stripper.* Not compatible with some non-Japanese brand modular plugs.SizesWeightgFCC standard modular plugs,RJ-11 / 12 (4 / 6 wires)135
For F connectorsSizesWeightgSleevesCenter contactsmmφ5C / 7C2.0 / 2.3 / 2.6320Warning●The handle cover is not insulated. Do not use where electrical currents exist.
For uninsulated terminals and connectors (B / P)* Not equipped with a forming check mechanism. (The crimping force when the handle is completely closed is equivalent to the JIS standard.)Weight275gNominal sizesCrimp marking1.25122Manual
For insulated closed end terminalsWeight315 gNominal sizesCrimp markingCE11CE22CE55ManualWarning●The handle cover is not insulated. Do not use where electrical currents exist.■Replacement partP-726-1SPRING■For P-726 / P-736 / P-741 / P-743
For BNC / TNC connectors●Crimper for BNC/TNC/BNCC connectors.Connector and die correspondence tableCompatible connector outer dia. sizemmConnector manufacturerWeightgCenter contactSleeve2.16.5 / 9.2Nanaboshi Electric Mfg. Co.Toyo Connector Co.350Warning●The handle cover is not insulated. Do not use where electrical currents exist.Manual
For BNC / TNC connectors●Crimper for BNC/TNC/BNCC connectors.Connector and die correspondence tableCompatible connector outer dia. sizemmConnector manufacturerWeightgCenter contactSleeve1.756.8 / 9.0Canare Electric Co.Toyo Connector Co.375Warning●The handle cover is not insulated. Do not use where electrical currents exist.
For open end conectorsSizesSmall (1.6 × 2)SmallMediumLargeWeight430 gManualWarning●The handle cover is not insulated. Do not use where electrical currents exist.■Replacement partP-77-6SPRING■For P-75 / P-77
For insulated terminals and connectors●The handle's adjustable opening width allows the tool to be used while in small width condition.Nominal sizesConnector manufacturerCompatible wire sizes (reference)Crimp markingWeightAWG#mm20.5*JST / Fuji Terminal Industry24 to 220.2 to 0.3●365 g0.3 / 0.5*Common to all manufacturers24 to 200.2 to 0.5●●1.2520 to 160.5 to 1.651216 to 141.04 to 2.632* For JST and Fuji Terminal Industry brand "noted terminals" with a nominal size of 0.5, and a wire size of 0.2 to 0.3 mm2, the appropriate die must be selected according to the wire type.ManualWarning●The handle cover is not insulated. Do not use where electrical currents exist.